Siguran AQ Smart

Fast 5 secondsTest Time

Sinodraw Patent Lancing Device

pregled
  • pregled

    The Safe AQ Smart Blood Glucose Monitoring System is designed for the quantitative measurement of glucose in fresh capillary whole blood samples taken from the fingertip and in venous whole blood samples. The Blood Glucose Monitoring System is for use outside the body only (in vitro diagnostic use) for self-testing and professional use as an aid in the management of diabetes.

  • Princip ispitivanja

    A blood glucose test is based on measurement of electrical current caused by the reaction of glucose with the reagents (special chemicals) on the electrode of the strip. The blood or control solution sample is drawn into the tip of the test strip through capillary action. Glucose in the sample reacts with the special chemicals and generates electrons, which produce electrical current. The blood glucose meter measures the electrical current and calculates the glucose result. The glucose result is displayed by your meter as mg/dL or mmol/L.

  • Karakteristike (tehničke prednosti)

    1) FAD-GDH sistem: Molekul kisika u krvi ne utječe lako na njega.

    2) Korisnički prilagođen operativni sistem: bez kodiranja i automatskog izbacivanja test traka u upravljanju dijabetesom.

specifikacija
Zapremina krvi 0.6μL
Vrsta uzorka Kapilarna cijela krvava cijela krv
kalibrisanje Ekvivalent plazme
Merenje vremena 5s
Stanje skladištenja / transporta brojila -20~ 55 ℃
dimenzija 84 * 60 * 26 (mm)
Težina 73.5g, with battery
Izvor napajanja 3V DC, 50mA, 2 AAA alkalne baterije
memorija 10 testova glukoze u krvi
Radno stanje 10 ~ 35; ≤80% RH
izgradnja Ručni
Mjerne jedinice mg / dL ili mmol / L
Merni opseg 20 ~ 600 mg / dL ili 1.1 ~ 33.3 mm / L
Rok trajanja 10 godina (procjenjuje se testom 7 puta dnevno).
Tokom upotrebe, korisnik treba održavati proizvod
pogledajte zahtjeve ovog korisničkog priručnika.
Karakteristike performansi

Accuracy: 95% test result of Safe AQ meet the requirement below:


Raspon koncentracije Pristranost%
<5.5 mmol / L (100 mg / dL) Unutar ± 0.83 mmol / L (15 mg / dL)
25.5 mmol / L (100 mg / dL) Unutar ± 15%


Precision: test result of Safe AQ Smart meet the requirement below:


Raspon koncentracije Zahtijevaj
<5.5 mmol / L (100 mg / dL) SD <0.34 mmol / L (6.0 mg / dL)
25.5 mmol / L (100 mg / dL) CV <6.0%


                               