EN
ĉiuj Kategorioj
EN

Sekura AQ UG

Bi-functional blood glucose and uric acid monitoring system;  Automatic strips ejection; ISO15197 2013 approved;  Smart code for uric acid test

Superrigardo

      The Safe AQ UG Blood Glucose and Uric Acid Monitoring System is designed for the quantitative measurement of glucose and uric acid in fresh capillary whole blood samples and in venous whole blood samples. The Safe AQ UG Blood Glucose and Uric Acid Monitoring System is for use outside the body only (in vitro diagnostic use) for self-testing and professional use as an aid in the management of diabetes and hyperuricemia (HUA).

specifo
Testo FunkcioSanga GlukozoUrea Acido
Testa metodoFAD-GDHOksizita Ferocena Derivaĵo
SpecimenospecoEkstercentra kapilara tuta sango / vejna tuta sangoEkstercentra kapilara tuta sango / vejna tuta sango
Sango-specimeno
0.6µl3µl
Testa gamo20-600mg / dL
 (1.1-33.3mmol / L)
3.0-20.0mg / dL
(181-1188 µmol/L)
Testotempo5s25s
memoro500 aroj100 aroj
Striigi validecon24 monatoj12 monatoj
◆ Takso de rendimento de uzanto de sango-glukozo:
Rezultoj por glukozaj koncentriĝoj <100 mg / dL (<5.55mmol / l)
Ene de ± 5mg / dL
(ene de ± 0.28mmol / l)
Ene de ± 10mg / dL
(ene de ± 0.56mmol / l)
Ene de ± 15mg / dL
(ene de ± 0.83mmol / l)
50% (14/28)85.71% (24/28)100% (28/28)
                Rezultoj por glukozaj koncentriĝoj ≥ 100 mg / dL (≥5.55mmol / l)
Ene de ± 5%
Ene de ± 10%
Ene de ± 15%
55.56% (40/72)90.28% (65/72)97.22% (70/72)
◆ Uric acid user performance evaluation:
Results for uric acid concentrations < 297μmol/L (5.0 mg/ dL)
Within ± 14.9μmol/L
(Within ± 0.3 mg/ dL)
Within ± 29.7μmol/L
(Within ± 0.5 mg/ dL)
Within ± 59.4μmol/L
(Within ± 1.0 mg/ dL)
40.0% (6/15)60.0% (9/15)100% (15/15)
                Results for uric acid concentrations≥ 297μmol/L (5.0 mg/ dL)
Ene de ± 5%
57.6% (49/85)
Ene de ± 10%
94.1% (80/85)
Ene de ± 15%
100% (85/85)