EN
sve kategorije
EN

Višenamjenska serija za nadzor

Siguran AQ UG

Bi-functional blood glucose and uric acid monitoring system; Automatic strips ejection; ISO15197 2013 approved; Smart code for uric acid test

Pregled

The Safe AQ UG Blood Glucose and Uric Acid Monitoring System is designed for the quantitative measurement of glucose and uric acid in fresh capillary whole blood samples and in venous whole blood samples. The Safe AQ UG Blood Glucose and Uric Acid Monitoring System is for use outside the body only (in vitro diagnostic use) for self-testing and professional use as an aid in the management of diabetes and hyperuricemia (HUA).

Specifikacija
Funkcija ispitivanja Glukoza u krvi Uric Acid
Metoda ispitivanja FAD-GDH Oxidized Ferrocene Derivative
Vrsta uzorka Peripheral capillary whole blood/venous whole blood Peripheral capillary whole blood/venous whole blood
Uzorak krvi
0.6μl 3μl
Raspon ispitivanja 20-600mg / dL
(1.1-33.3mmol/L)
3.0-20.0mg / dL
(181-1188 µmol/L)
Vrijeme ispitivanja 5s 25s
memorija 500 postavlja 100 postavlja
Strip validity 24 mjeseci 17 mjeseci
◆ Blood glucose user performance evaluation:
Results for glucose concentrations<100 mg/dL (<5.55mmol/l)
Within ± 5mg/dL
(within ± 0.28mmol/l)
Within ± 10mg/dL
(within ± 0.56mmol/l)
Within ± 15mg/dL
(within ± 0.83mmol/l)
50%(14/28) 85.71% (24/28) 100% (28/28)
Results for glucose concentrations ≥ 100 mg/dL (≥5.55mmol/l)
Within ± 5%
Within ± 10%
Within ± 15%
55.56%(40/72) 90.28%(65/72) 97.22%(70/72)
◆ Uric acid user performance evaluation:
Results for uric acid concentrations < 297μmol/L (5.0 mg/ dL)
Within ± 14.9μmol/L
(Within ± 0.3 mg/ dL)
Within ± 29.7μmol/L
(Within ± 0.5 mg/ dL)
Within ± 59.4μmol/L
(Within ± 1.0 mg/ dL)
40.0%(6/15) 60.0% (9/15) 100% (15/15)
Results for uric acid concentrations≥ 297μmol/L (5.0 mg/ dL)
Within ± 5%
57.6%(49/85)
Within ± 10%
94.1%(80/85)
Within ± 15%
100%(85/85)