Best choice for the early screening of renal disease

Overview
  • Նախատեսված է օգտագործման համար

    The PABA-1000 ACR Analyzer is intended to be used with the mALB/Cr Reagent Kit manufactured by Changsha Sinocare Inc. to quantitatively determine microalbuminuria, creatinine and ACR (the ratio of microalbuminuria and creatinine) in urine sample. It is for in vitro diagnostic use only. It is intended for prescription point-of-care use as an aid in the diagnosis of renal disease.

  • Աշխատանքային Principle

    The ACR of tested sample is determined by colorimetry (Cr) and fluorometry (mALB). When passing through tested solution, one light beam is absorbed by Solution A, while another light beam excites the fluorescent substances in Solution B. The content of tested substance, which is clinically significant, can be acquired by analyzing the amount of absorbed light or generated florescence.

  • Փաթեթավորման ցուցակ

    ACR Monitoring System consists of PABA-1000 ACR analyzer, mALB/Cr Reagent Kit and control solutions (level 1, level 2). The mALB/Cr Reagent Kit is intended to be used with the PABA-1000 ACR Analyzer to quantitatively determine microalbuminuria, creatinine and ACR (the ratio of microalbuminuria and creatinine) in urine sample.



Diabetes is the leading cause for the end-stage renal disease


▼In developed countries, about 1/3 of diabetic patients have diabetic kidney disease, which is the main cause of renal failure 1,2

▼According to the DEMAND study, the detection rate of albuminuria in Asian diabetic patients was 56%, higher than that in Caucasian patients (41%) , Early detection of renal dysfunction may arrest/delay the progression of renal failure





5


6


4

մասնագիր
կետ Parameter
Նմուշի տեսակը Մեզ
Ռեակտիվ

mALB(MAU)/Creatinine test kit

(fluorescence and Benedict-Behre Methods)

Լեզու
English / simplified Chinese
ցուցադրել 5-inch touch screen
Զրույց նավահանգիստ RS232,USB,RJ45
Power մուտք ~220V,50Hz,1.4A
Չափերը 380mm×240mm×254mm(L×W×H)
Զտաքաշ
6.5kg
Տպիչ
Ներկառուցված ջերմային տպիչ
Single test time About 6 min
Data storage volume 2000 test and quality control data
կետ

Մեթոդաբանությունը

Շարք Դիպուկություն

mALB (MAU)

Fluorescence scattering 5.0mg/L-200.0mg/L

5.0~30.0mg/L

SD2.0mg/L;

30.1~200.0mg/L,CV6.5%
Creatinine Benedict-Behre

10.0-400.0mg / dL

(0.88-35.30mmol/L)

10.0-60.0mg/dL SD3.0mg/dL;

60.1-400.0mg/dL CV5%
ACR /

1.3-2000.0mg/g

(0.14-227.28mg/mmol)
CV10%

Sinocare #ACR Analyzer video introduction in English