EN
ທຸກຫມວດຫມູ່
EN

ປອດໄພ AQ UG

Bi-functional blood glucose and uric acid monitoring system;  Automatic strips ejection; ISO15197 2013 approved;  Smart code for uric acid test

ພາບລວມ

      The Safe AQ UG Blood Glucose and Uric Acid Monitoring System is designed for the quantitative measurement of glucose and uric acid in fresh capillary whole blood samples and in venous whole blood samples. The Safe AQ UG Blood Glucose and Uric Acid Monitoring System is for use outside the body only (in vitro diagnostic use) for self-testing and professional use as an aid in the management of diabetes and hyperuricemia (HUA).

ຂໍ້ມູນ
Function ທົດສອບເລືອດກູໂກອາຊິດ uric
ວິທີການທົດສອບFAD-GDHOxidized Ferrocene Derivative
ປະເພດຕົວຢ່າງPeripheral capillary ເລືອດ / ເສັ້ນເລືອດທັງ ໝົດPeripheral capillary ເລືອດ / ເສັ້ນເລືອດທັງ ໝົດ
ຕົວຢ່າງເລືອດ
0.6µl3µl
ຊ່ວງທົດສອບ20-600mg / dL
 (1.1-33.3mmol / L)
3.0-20.0mg / dL
(181-1188 µmol/L)
ເວລາທົດສອບ5s25
ຫນ່ວຍຄວາມຈໍາຊຸດ 500ຊຸດ 100
ຄວາມຖືກຕ້ອງລອກເອົາເດືອນ 24ເດືອນ 12
evaluation ການປະເມີນຜົນຂອງຜູ້ຊົມໃຊ້ໃນລະດັບ glucose ໃນເລືອດ:
ຜົນໄດ້ຮັບ ສຳ ລັບຄວາມເຂັ້ມຂຸ້ນຂອງນ້ ຳ ຕານ <100 mg / dL (<5.55mmol / l)
ພາຍໃນ± 5mg / dL
(ພາຍໃນ± 0.28mmol / l)
ພາຍໃນ± 10mg / dL
(ພາຍໃນ± 0.56mmol / l)
ພາຍໃນ± 15mg / dL
(ພາຍໃນ± 0.83mmol / l)
50% (14/28)85.71% (24/28)100% (28/28)
                ຜົນໄດ້ຮັບ ສຳ ລັບຄວາມເຂັ້ມຂຸ້ນຂອງນ້ ຳ ຕານ≥ 100 mg / dL (≥5.55mmol / l)
ພາຍໃນ± 5%
ພາຍໃນ± 10%
ພາຍໃນ± 15%
55.56% (40/72)90.28% (65/72)97.22% (70/72)
◆ Uric acid user performance evaluation:
Results for uric acid concentrations < 297μmol/L (5.0 mg/ dL)
Within ± 14.9μmol/L
(Within ± 0.3 mg/ dL)
Within ± 29.7μmol/L
(Within ± 0.5 mg/ dL)
Within ± 59.4μmol/L
(Within ± 1.0 mg/ dL)
40.0% (6/15)60.0% (9/15)100% (15/15)
                Results for uric acid concentrations≥ 297μmol/L (5.0 mg/ dL)
ພາຍໃນ± 5%
57.6% (49/85)
ພາຍໃນ± 10%
94.1% (80/85)
ພາຍໃນ± 15%
100% (85/85)





ຕິດ​ຕໍ່​ພວກ​ເຮົາ