PABA 1000
Sarudzo yakanakisa yeiyo kutanga kuongororwa kwechirwere chetsvo

tsananguro
Kushandiswa kwakashandiswa
Iyo PABA-1000 ACR Analyzer inoitirwa kuti ishandiswe neMALB / Cr Reagent Kit inogadzirwa naChangsha Sinocare Inc. kugadzirisa huwandu hwealbuminuria, creatinine uye ACR (iyo ratio ye microalbuminuria uye creatinine) mune weti sampuro. Izvo ndezve in vitro diagnostic use chete. Izvo zvakagadzirirwa kunyorerwa poindi-ye-yekuchengetedza kushandiswa seyamuro mukuongororwa kwechirwere chetsvo.
Working Principle
Iyo ACR yemuyedzo sampuro inotemwa ne colorimetry (Cr) uye fluorometry (mALB). Paunenge uchipfuura nemuyedzo wakaedzwa, danda rimwe remwenje rinosanganiswa neSolution A, nepo rimwe danda remwenje richinakidza zvinhu zvefluorescent muSolution B. Izvo zvemukati mezvinhu zvakaedzwa, izvo zvakakosha pakiriniki, zvinogona kuwanikwa nekuongorora huwandu hwenzvimbo yemwenje kana inogadzirwa. florescence.
Packing runyorwa
ACR Monitoring System ine PABA-1000 ACR analyzer, mALB / Cr Reagent Kit uye mhinduro dzekugadzirisa (nhanho 1, danho 2). Iyo mALB / Cr Reagent Kit inoitirwa kuti ishandiswe nePABA-1000 ACR Analyzer kuti zvinyatso sarudza microalbuminuria, creatinine uye ACR (iyo ratio ye microalbuminuria uye creatinine) mune weti sampuro.
Chirwere cheshuga ndicho chinokonzera kukonzera kumagumo-danho renal chirwere
▼ Munyika dzakasimukira, inenge 1/3 yevarwere vechirwere cheshuga vane chirwere chetsvo cheshuga, chinova chikonzero chikuru chekutadza kweitsvo 1,2
▼ Zvinoenderana neCHIDZIDZO chekudzidza, chiyero chekuonekwa kwealbininuria muAsia varwere vane chirwere cheshuga chaive 56%, chakakwirira kupfuura icho chevarwere veCaucasian (41%), Kuonekwa kwekutanga kweiyo renal kudzvinyirira kunogona kusunga / kunonoka kufambira mberi kwekukundikana kwetsvo
Specification
chinhu | Parameter |
---|---|
Mhando yemhando | Urine |
Reagent | mALB (MAU) / Creatinine bvunzo kit (fluorescence uye Benedict-Behre Maitiro) |
mutauro | Chirungu / chakareruka Chinese |
kuratidza | 5-inch touch screen |
Chiteshi chekutaurirana | RS232 , USB , RJ45 |
Power chiyamuro | ~ 220V, 50Hz, 1.4A |
miganhu | 380mm × 240mm × 254mm, L × W × H, |
Net uremu | 6.5kg |
purinda | Inovakwa-inodziya printer |
Imwe bvunzo nguva | About 6 min |
Dhata yekuchengetedza vhoriyamu | 2000 bvunzo uye mhando kutonga data |
chinhu | Methodology | dungwerungwe | zvakarurama |
MALB (MAU) | Fluorescence ichipararira | 5.0mg / L-200.0mg / L | 5.0 ~ 30.0mg / L SD≤2.0mg / L; 30.1 ~ 200.0mg / L,CV≤6.5% |
Creatinine | Benedict-Behre | 10.0-400.0mg / dL (0.88-35.30mmol / L) | 10.0-60.0mg / dL SD≤3.0mg / dL; 60.1-400.0mg / dL CV≤5% |
ACR | / | 1.3-2000.0mg / g (Zvikamu 0.14-227.28mg / mmol) | CV≤10% |
Sinocare #ACR Analyzer vhidhiyo yekuburitsa muChirungu