I-AQ ekhuselekileyo
Fast 5 secondsTest Ixesha
Isixhobo seSinodraw Patent Lancing

isishwankathelo
isishwankathelo
I-Safe AQ Smart Blood Monitoring System yenzelwe ubungakanani bomlinganiselo weswekile kwiisampulu zegazi ze-capillary ezithathwe kwincam yomnwe kunye neesampulu zegazi elipheleleyo le-venous. I-Blood Glucose Monitoring System isetyenziselwa ukusetyenziswa ngaphandle komzimba kuphela (ukusetyenziswa kwe-in vitro diagnostic) ukuzivavanya kunye nokusetyenziswa kobuchwephesha njengoncedo ekulawuleni isifo seswekile.
Umgaqo wokuvavanya
A blood glucose test is based on measurement of electrical current caused by the reaction of glucose with the reagents (special chemicals) on the electrode of the strip. The blood or control solution sample is drawn into the tip of the test strip through capillary action. Glucose in the sample reacts with the special chemicals and generates electrons, which produce electrical current. The blood glucose meter measures the electrical current and calculates the glucose result. The glucose result is displayed by your meter as mg/dL or mmol/L.
Iimpawu (iinzuzo zobugcisa)
I-1) Inkqubo ye-FAD-GDH : Ayichaphazeli lula i-oxygen molecule egazini.
2) Inkqubo yokusebenza esebenziseka lula: akukho khowudi kunye novavanyo oluzenzekelayo lwe-strip ejection kulawulo lweswekile.
Specification
Umthamo wegazi | 0.6μL |
Uhlobo lwesampulu | I-Capillary igcwele igazi elipheleleyo |
Ukulinganisa | Iplasma ilingana |
Ixesha lokulinganisa | 5s |
Ukugcinwa kweemitha / imeko yokuthutha | -20℃~ 55 ℃ |
Dimension | I-84 * 60 * 26 (mm) |
ubunzima | 73.5g, enebhetri |
Power umthombo | 3V DC, 50mA, 2 AAA iibhetri ezinealkali |
Imemori | Iziphumo zovavanyo lweswekile yegazi ezingama-10 |
Imeko yokusebenza | 10℃~35℃; ≤80% RH |
ukwakhiwa | Ebanjwe ngesandla |
Iiyunithi zokulinganisa | mg / dL okanye mmol / L |
Uluhlu lwesilinganiselo | 20–600 mg/dL okanye 1.1–33.3mmo/L |
Beka ubomi kwishelufa | Iminyaka eli-10 (iqikelelwa ngovavanyo amaxesha esi-7 ngosuku). Ngexesha lokusetyenziswa, umsebenzisi kufuneka agcine imveliso jonga kwiimfuno zale ncwadi yomsebenzisi. |
Iimpawu zobume
Accuracy: 95% test result of Safe AQ meet the requirement below:
Uluhlu loxinzelelo | Ukwahlula% |
---|---|
ngaphantsi kwe-5.5 mmol/L(100 mg/dL) | Ngaphakathi kwe-±0.83 mmol/L(15 mg/dL) |
25.5 mmol/L(100mg/dL) | Ngaphakathi ± 15% |
Precision: test result of Safe AQ Smart meet the requirement below:
Uluhlu loxinzelelo | Funa ingcebiso |
---|---|
ngaphantsi kwe-5.5 mmol/L(100 mg/dL) | SD<0.34mmol/L(6.0mg/dL) |
25.5 mmol/L(100mg/dL) | I-CV <6.0% |